Model | Orbital Diameter | Platform | SKU | Price |
---|---|---|---|---|
5°C above ambient temperature to 60°C | 0.75" Orbit | Without Platform | EPP:M1344-0000 |
$9,338
|
5°C above ambient temperature to 60°C | 0.75" Orbit | With Universal Platform | EPP:M1344-0000+M1250-9902 |
$10,277
|
15°C above ambient temperature to 60°C | 0.75" Orbit | Without Platform | EPP:M1344-0004 |
$10,931
|
5°C above ambient temperature to 60°C | 1" Orbit | Without Platform | EPP:M1344-0010 |
$9,338
|
5°C above ambient temperature to 60°C | 1" Orbit | With Universal Platform | EPP:M1344-0010+M1250-9902 |
$10,277
|
15°C above ambient temperature to 60°C | 1" Orbit | Without Platform | EPP:M1344-0014 |
$10,931
|
The New Brunswick model I24 and I24R compact biological shakers fit on your bench. A large clear lid enables easy viewing of your culture media. The model I24 is available with incubation only or incubation and refrigeration in the model I24R. These models feature New Brunswick triple-eccentric counterbalanced shaking mechanism for uniform motion and years of quiet, dependable operation. Microprocessor controls with digital display enable easy operation and accurate setpoint regulation. A large assortment of platforms, clamps, test tube holders and other accessories allow configuration to meet your exact needs.
Features:
Cu ft. | 3.348 |
Max Temp | 60°C |
Min Temp | Ambient +5°C or Ambient -15°C |
Temp Uniformity | ±0.1 °C at 37 °C |
Interior Outlets | No |
Alarms | Yes |
Datalogging Capable | RS-232 access |
Warranty (years) | 2 |
Site | Benchtop |
Weight (lbs) | 138, 184 |
Model | I24 | I24R |
---|---|---|
Speed | 25 – 500 rpm | |
Control Accuracy | ±1 rpm | |
Indication | Displayed in 1 rpm increments | |
Stroke/orbit | 1.9 cm (¾ in) or 2.5 cm (1 in) | |
Temp Range | 5°C above ambient temperature to 60°C | 15°C below ambient temperature (minimum 4°C) to 60°C |
Control Accuracy | ±0.1 °C at 37 °C | |
Indication | Displayed in 0.1 °C increments | |
Heaters | Long-life, low-watt density resistance-type heater with high temperature thermostat | |
Width | 55.8 cm (22 in) | |
Depth | Front to back: 76.2 cm (30 in) | |
Height | 61.1 cm (24 1/16 in), With lid open: 101.9 cm (40 1/8 in) | |
Chamber width | 51.7 cm (20 3/8 in) | |
Chamber depth | 53.3 cm (21 in) | |
Chamber height | 34.4 cm (13 9/16 in) | |
Platform width | 46 cm (18 in) | |
Platform depth | 46 cm (18 in) | |
Weight | 24 weight: 62.7 kg (138 lbs) | 24R weight: 83.6 kg (184 lbs) |
Altitude limit | 2000 m | |
Alarms | Visible and audible warning indication when speed deviates more than 5 rpm or temperature more than 1°C from setpoints, and when timer has expired. Audible alarm can be muted | |
LED display | 1.4 cm (9/16 in) | |
RS-232 | Data logging | |
Setpoint retention | All setpoints and operating status are retained in non-volatile memory | |
Automatic restart | Automatic restart after power is restored, indicated by flashing display | |
Drive | Triple eccentric counterbalanced drive with nine permanently lubricated ball bearings | |
Drive motor | Solid-state brushless DC motor | |
Safety | Independent mechanical sensing tilt switch shuts off the motor in an unbalanced condition Drive Interrupt shuts off power to shaker when door opens Acceleration/deceleration circuit prevents sudden starts and stops, minimizing both splashing and mechanical damage |
|
Electrical requirements | 120 V, 60 Hz | |
ETL regulatory standards | UL61010A-1 UL61010A-2-010 |