Title | SKU | Price |
---|---|---|
Default Title | SL:SSI3 |
$6,187
|
The SSI3 incubated benchtop orbital shaker has a transparent hood that lifts up via a hydraulic system so it will function in tight places. All of our shaking incubators feature stainless steel interiors which provide excellent durability and an easy-to-clean surface. Each unit has an easy-to-read LED display. The rotation platform is included with each unit and is self-centering for easy installation.
All major functions -- temperature, RPM and time -- have alarms that alert the user to deviations from set parameters. Overtemperature protection is provided via a safety thermostat. Digital keypad operation offers the ability to calibrate the temperature controller to a reference thermometer.
To better support the load over years of constant use, we utilize four load bearing positions for optimal weight distribution. Features include:
Cu ft. | 3.3 |
Max Temp | 60°C |
Min Temp | Ambient +8°C |
Temp Uniformity | ± 0.5°C |
Interior Outlets | No |
Alarms | Yes |
Datalogging Capable | No |
Warranty (years) | 2 |
Site | Benchtop |
Weight (lbs) | 75 |
Agency Approval | UL, CSA and EU Approved | |
Oscillation Rate | 30-400 rpm, +/-4 rpm (1rpm increments) | |
Temperature Uniformity | +/-0.5°C at 37°C | |
Temperature Range | Ambient +8°C to 60°C | |
Platform Dimensions | 17 x 18 x .75" (44 x 45 x 2cm) | |
Exterior Dimensions WxDxH in. (cm) | 22 x 25.5 x 28 (55.9 x 64.8 x 71.2) | |
Interior Dimensions WxDxH in. (cm) | 19 x 18 x 16.5 (48.2 x 45.7 x 41.9) | |
Capacity | 3.3 cu.ft. (92 L) | |
Overtemperature Alarm | Yes | |
Nominal Voltage 50/60HZ (V) | 110-120/220-240 | |
Maximum Energy Consumption (W) | 840 | |
Maximum Load | 18 lb (8 kg) |
All specifications are determined by using average values on standard equipment at an ambient temperature of 25°C (77°F) and line voltages within +/-10% of unit type (115V/230V). Temperature specifications follow DIN 12880 methodology.
What is the orbit diameter of the SSI3 Shaking Incubator?
The orbit diameter of the SSI3 Benchtop Shaking Incubator can be adjusted to either 0.5, 0.75, or 1 inch. You can perform this adjustment in your lab by repositioning the counterweights and shaker arms that are located underneath the shaking platform, which is removable. The process does not require tools nor any technical knowledge, and is explained with pictures in the manual. If you would like an up-to-date manual for the SSI3, please email us and we will send you the latest version.
8161 Sheldon Manufacturing 2017-06-04