Size | Humidity Control | CO2 Control | SKU | Price |
---|---|---|---|---|
10.6 Cu ft. | No (TL) | No | JT:AAHA1011K |
$12,785
|
10.6 Cu ft. | No (TL) | Yes | JT:AAHA1011K+AAAA1521 |
$16,972
|
10.6 Cu ft. | Yes (TLH) | No | JT:AAHA1021K |
$17,611
|
10.6 Cu ft. | Yes (TLH) | Yes | JT:AAHA1021K+AAAA1521 |
$21,798
|
35.3 Cu ft. | Yes (TLH) | No | JT:AAHA1031K |
$27,283
|
35.3 Cu ft. | Yes (TLH) | Yes | JT:AAHA1031K+AAAA1521 |
$31,470
|
Optimal photosynthesis condition guaranteed when using our plant growth chamber.
Ample capacity, maximum capacity of 1000L to satisfy user's plant growth needs
Models: GC-300TL/300TLH/1000TLH
Performance
General control system
Illuminance control system
Convenience
Safety
Lamps setting
PLEASE NOTE: All Jeio Tech environmental chambers are manufactured to order. A lead time of approximately 12 weeks should be expected.
Some accessories are factory install only and must be ordered at time of Incubator purchase for factory installation at time of manufacture.
Cu ft. | 10.6, 35.3 |
Max Temp | 50°C |
Min Temp | 5°C |
Temp Uniformity | ± 0.5°C |
Interior Outlets | No |
Alarms | Yes |
Datalogging Capable | Yes |
Warranty (years) | 1 (2 years after submission of warranty registration card) |
Site | Floor |
Weight (lbs) | 551, 1213 |
Model | GC-300TL | GC-300TLH | GC-1000TLH | ||||
---|---|---|---|---|---|---|---|
Chamber volume (L / cu ft) |
300 / 10.6 |
1000 / 35.3 |
|||||
Control system |
Microprocessor PID controller |
||||||
Temperature |
Range (℃ / ℉) |
5 to 50 / 41 to 122 - Lamp off |
|||||
10 to 50 / 50 to 122 - Lamp on |
|||||||
20 to 50 / 68 to 122 - with humidity |
|||||||
Fluctuation (±℃ / ℉) at 25℃ |
0.1 / 0.18 - without humidity |
||||||
Variation (±℃ / ℉) at 25℃ |
0.8 / 1.43 - without humidity |
||||||
Illumination |
Range (Lux) |
0 to 20,000 |
0 to 35,000 |
||||
Control (steps) |
10 |
11 |
|||||
Lamp |
Fl lamp (32W×18ea) |
FL lamp (32W×16ea) |
|||||
Metal lamp (400W×3ea) |
|||||||
Humidity |
Range (% RH) |
- |
40 to 80 at 20 to 35℃ |
50 to 90 at 20 to 35℃ |
|||
70 to 90 at 36 to 50℃ |
60 to 90 at 36 to 50℃ |
||||||
Fluctuation (±RH) at 60% RH |
- |
3 |
|||||
Co2(optional) |
Range (ppm) |
Max. 5,000 |
|||||
Sensor |
NDIR CO2 sensor |
||||||
Refrigerant (HP) |
1/2 |
3/4 |
|||||
Temp. heater power (W) |
750×2ea |
1,500×2ea |
|||||
Humid. heater power (W) |
- |
1300 |
1500 |
||||
Dimension (W×D×H) |
Interior (mm / inch) |
510×540×1100 / 20×21.3×43.3 |
1200×800×1080 / 47.2×31.5×42.5 |
||||
Exterior (mm / inch) |
700×805×1900 / 27.6×30.1×74.8 |
1410×1070×2150 / 55.5×42.1×84.7 |
|||||
Net weight (kg / lbs) |
250 / 551.2 |
550 / 1212.5 |
|||||
Electrical requirements (230V) | 60Hz / 12.5A | 60Hz / 16A | 60Hz / 30A | ||||
Cat. No. | AAHA1011K | AAHA1021K | AAHA1031K |
What kind of lights do the GC Plant Growth Chambers use?
They use 32 W fluorescent bulbs.
Does the GC-1000TLH have two independently controlled chambers?
No, the GC-1000TLH has two doors which lead into a single chamber.
14988 Jeio Tech 2017-07-07